We have over 200 types of industrial boilers, including gas / oil fired boiler, hot water boilers, steam boiler and etc. If you are interested in our products or company, just feel free to contact us.
Available Fuel: Bituminous coal...
Available Fuel: Nature gas, coke oven gas...
I O m Hmr 0.11 m Hr 0.68 m OPT 1 377 Pa Control of in-bed agglomeration section. The overall length of the reactor was 4.6 m. As discussed previously, the disengagement section was intended to reduce the velocity of the combustion gas in the disengagement zone and promote the internal recirculation of fuel and bed particles entrained on the flow.
2019-8-19·Details:Vision Sponge Iron Pvt Ltd, Madhukunda (W.B) From September 2016 to July 2017 as an Instrument Engineer. A Power Plant with AFBC (1×36 TPH) Boiler, 4 WHRB (4×10 TPH) Boilers and TG is (1×15 MW).
I O m Hmr 0.11 m Hr 0.68 m OPT 1 377 Pa Control of in-bed agglomeration section. The overall length of the reactor was 4.6 m. As discussed previously, the disengagement section was intended to reduce the velocity of the combustion gas in the disengagement zone and promote the internal recirculation of fuel and bed particles entrained on the flow.
O & M Manual for Boiler . Comments. Content.. OPERATION & MAINTENANCE MANUAL This boiler is AFBC design, BI-Drum, outdoor, natural circulation, Water tube, fluidised bed combustion, Underbed Fuel Feeding System, balance draft, Bottom Supported with STEEL construction & Hopper Bottom design. Dont leave the Instrument Control Panel
Having Experience of Project & Maintenance in 60 MW, 12 MW, 20 MW and 36.5 MW Thermal Power Plant and 35 TPD Bromine Plant. it consist PF Boiler, WHRB Boiler, AFBC Boiler & CFBC Boiler respectively and Turbine (SHANDONG JINAN, HITACHI, Skoda &
Cv 1. CURRICULUM VITAE R.JAYAKUMAR E-mail:[email protected] 1/99, mn.palayam, Skype Id: grjayakumar Porkunam (post), Phone: 0097455170165(Qatar) Thiruvannamalai (District), Tamil Nadu -606802 CAREER OBJECTIVE Presently working with QD-SBG, Hamad International Airport, and Doha, Qatar as Instrument/Low current Engineer.
Case Study 31: Installation of Variable Frequency Drive for Control of ID Fans in place of Inlet Damper Control in Pulp & Paper Industry Brief 50 tph AFBC boiler was provided with 2 nos. ID fans. The furnace draft was being controlled by varying the inlet damper position of
A boiler requires a source of heat at a sufficient tem-perature to produce steam. Fossil fuel is generally burned directly in the boiler furnace to provide this heat although waste energy from another process may also be used. Combustion is defined as the rapid chemical com-bination of oxygen with the combustible elements of a fuel.
2019-8-19·Details:Vision Sponge Iron Pvt Ltd, Madhukunda (W.B) From September 2016 to July 2017 as an Instrument Engineer. A Power Plant with AFBC (1×36 TPH) Boiler, 4 WHRB (4×10 TPH) Boilers and TG is (1×15 MW).
Taken active part in the commissioning of the 90TPH AFBC Boiler and 21MW Turbine-Preparation of preliminary P&IDs in co-ordination with process and piping personnel.-Finalization of P&IDs based on process requirements and instrument design criteria.-Preparation of technical specifications / data sheets for all the instruments & systems.
O & M Manual for Boiler . Comments. Content.. OPERATION & MAINTENANCE MANUAL This boiler is AFBC design, BI-Drum, outdoor, natural circulation, Water tube, fluidised bed combustion, Underbed Fuel Feeding System, balance draft, Bottom Supported with STEEL construction & Hopper Bottom design. Dont leave the Instrument Control Panel
Call us, we are 24/7 Helpline
Copyright © 2020 Food Industry Boiler. All rights reserved.